PROMOTIVE AGM 670901100
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 170 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 1000 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 670901100
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- A2
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 513/223/223
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 629AGM
-
Capacity
-
ProMotive SHD 670104100
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 170 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 1000 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 670104100
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- M9
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 513/223/223
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 620HD
-
Capacity
-
ProMotive SHD 640400080
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 140 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 800 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 640400080
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- K8
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 513/189/223
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 630HD
-
Capacity
-
ProMotive HD 635042068
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 135 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 680 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 635042068
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- J8
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 360/253/240
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Classic 120018057
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 120 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 570 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 120018057
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- n/a
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 6 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 265/174/217
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Classic 112011054
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 135 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 540 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 112011054
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- n/a
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 6 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 280/174/217
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Classic 098011048
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 112 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 480 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 098011048
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- n/a
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 6 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 265/174/217
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Classic 084011039
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 84 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 390 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 084011039
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- n/a
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 6 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 225/174/217
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Classic 077015036
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 77 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 360 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 077015036
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- n/a
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 6 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 215/170/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Classic 066017036
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 66 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 360 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 066017036
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- n/a
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 6 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 177/175/185
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Classic 008011004
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 8 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 40 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 008011004
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- n/a
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 6 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 91/87/165
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Dual Purpose EFB 930240120
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 240 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 1200 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930240120
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LED240
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 518/276/242
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Dual Purpose 930231115
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 230 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 1150 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930231115
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LFD 230
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 518/276/242
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Dual Purpose EFB 930190105
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 190 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 1050 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930190105
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LED190
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 513/223/223
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Dual Purpose 930180100
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 180 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 1000 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930180100
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LFD 180
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 513/223/223
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Dual Purpose 930140080
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 140 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 800 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930140080
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LFD 140
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 513/189/223
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Dual Purpose EFB 930095085
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 95 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 850 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930095085
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LED95
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 353/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Starter 930095080
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 95 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 800 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930095080
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LFS 95
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 353/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Dual Purpose 930090080
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 90 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 800 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930090080
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LFD 90
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 353/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
-
Professional Dual Purpose EFB 930080080
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 80 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 800 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 930080080
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- LED80
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 315/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
-
Capacity
Do you work with batteries?
Trust a battery expert near you!
Deep dive into VARTA's battery Technology
AGM Advanced
Upgrade to AGM to get the best of the best - an outstanding battery to power your vehicle needs.
Got a question?
-
Although both AGM and EFB technologies are used for Start-Stop applications, there are some differences in the technologies' performance. While EFB is an improved flooded battery, AGM is a battery specifically designed for demanding applications and able to support any types of Start-Stop systems and eve xEV.
Downgrading from an AGM to an EFB is not recommended since the vehicle's Energy Management System is designed for a certain battery performance. Upgrading from EFB to AGM on the other hand, is always possible and advised when your customer faces recurring battery issues.
Find more on AGM, EFB, xEV and more in our Knowledge section.
-
The VARTA® Partner Portal provides partner workshops with assistance in this decision, with battery positions, battery selections and installation instructions for almost all vehicles which are in use in Europe.
For end customers, the VARTA® Battery Search is an ideal tool to find the right battery.
-
With the wide range of starter batteries with various technologies and power classes, the choice is often difficult.
For reliable engine cranks a sufficient CCA performance is crucial. For a long service life and best peace of mind, the battery technology (AGM, EFB, SLI) must match with the vehicle's energy demands. For energy demanding applications, especially for hoteling functions in Long-haul trucks or Caravans the capacity in combination with the recommended Depth-of-Discharge is crucial.
The VARTA® Partner Portal for our partner workshops and the VARTA® Battery Search for customers makes it easy to select the right battery.
-
Extending your battery's lifespan involves a few key practices:
- Disconnect cables: Always disconnect the negative terminal first to prevent short circuits, then disconnect the positive terminal.
- Check battery's state: For non-maintenance-free lead-acid batteries, visit a professional. For maintenance-free batteries, clean vent pipes and avoid checking electrolyte levels.
- Start charging: Keep the battery upright if removing from the car. Turn off electrical consumers before connecting the charger. Connect the red cable to positive terminal first, then the black cable to negative terminal.
- Stop charging: Switch off charger when fully charged. Disconnect cables starting with the red cable from positive terminal, then the black cable from negative terminal.
For more information find our article "How to extend the life of your battery".