• BLUE dynamic 580406074
    BLUE dynamic 580406074
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    80 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    740 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    580406074
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    F17
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/175/315
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    110
  • BLUE dynamic 580400074
    BLUE dynamic 580400074
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    80 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    740 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    580400074
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    F16
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/315
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    115
  • SILVER dynamic 577400078
    SILVER dynamic 577400078
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    77 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    780 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    577400078
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E44
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    096
  • BLUE dynamic EFB 575500073
    BLUE dynamic EFB 575500073
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    75 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    730 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    575500073
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E46
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/175/315
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    110EFB
  • SILVER dynamic 574402075
    SILVER dynamic 574402075
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    74 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    750 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    574402075
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E38
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/175/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    100
  • BLUE dynamic 574013068
    BLUE dynamic 574013068
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    74 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    680 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    574013068
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E12
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    086
  • BLUE dynamic 574012068
    BLUE dynamic 574012068
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    74 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    680 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    574012068
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E11
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    096
  • BLUE dynamic EFB 572501076
    BLUE dynamic EFB 572501076
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    72 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    760 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    572501076
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    N72
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/220/261
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    068EFB
  • BLUE dynamic 572409068
    BLUE dynamic 572409068
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    72 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    680 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    572409068
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E43
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/175/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    100
  • SILVER dynamic AGM 570901076
    SILVER dynamic AGM 570901076
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    760 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570901076
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    A7
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    096AGM
  • BLUE dynamic EFB 570500076
    BLUE dynamic EFB 570500076
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    760 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570500076
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    N70
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    096EFB
  • BLUE dynamic 570413063
    BLUE dynamic 570413063
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    630 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570413063
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E24
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/220/261
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    069
  • BLUE dynamic 570412063
    BLUE dynamic 570412063
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    630 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570412063
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E23
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/220/261
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    068
  • BLACK dynamic 570409064
    BLACK dynamic 570409064
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    640 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570409064
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E13
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    096
  • BLACK dynamic 570144064
    BLACK dynamic 570144064
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    640 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570144064
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E9
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/175/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    100
  • ProMotive HD 566047051
    ProMotive HD 566047051
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    66 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    510 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    566047051
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D33
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • BLUE dynamic EFB 565501065
    BLUE dynamic EFB 565501065
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    65 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    650 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    565501065
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    N65
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    173/225/232
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    005EFB
  • BLUE dynamic EFB 565500065
    BLUE dynamic EFB 565500065
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    65 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    650 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    565500065
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D54
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/175/278
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    100EFB
  • SILVER dynamic 563401061
    SILVER dynamic 563401061
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    63 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    610 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    563401061
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D39
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/242
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    077
  • SILVER dynamic 563400061
    SILVER dynamic 563400061
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    63 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    610 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    563400061
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D15
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    175/190/242
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    027

Do you work with batteries?

Explore VARTA®'s Training Academy and access exclusive
e-learnings. Dedicated to battery professionals only.

Trust a battery expert near you!

As cars become more and more complex so do their battery exchanges. That's why we do not recommend you to exchange your battery by yourself unless you are a battery professional. Instead, reach out to one of our trusted VARTA® Partner workshops instead

Deep dive into VARTA's battery Technology

AGM Advanced

Upgrade to AGM to get the best of the best - an outstanding battery to power your vehicle needs.

Learn More About AGM

 

Got a question?

  • Although both AGM and EFB technologies are used for Start-Stop applications, there are some differences in the technologies' performance. While EFB is an improved flooded battery, AGM is a battery specifically designed for demanding applications and able to support any types of Start-Stop systems and eve xEV.

    Downgrading from an AGM to an EFB is not recommended since the vehicle's Energy Management System is designed for a certain battery performance. Upgrading from EFB to AGM on the other hand, is always possible and advised when your customer faces recurring battery issues.

    Find more on AGM, EFB, xEV and more in our Knowledge section.

    Go to Knowledge

  • The VARTA® Partner Portal provides partner workshops with assistance in this decision, with battery positions, battery selections and installation instructions for almost all vehicles which are in use in Europe.

    For end customers, the VARTA® Battery Search is an ideal tool to find the right battery.

    Go to VARTA® Battery Finder

  • With the wide range of starter batteries with various technologies and power classes, the choice is often difficult.

    For reliable engine cranks a sufficient CCA performance is crucial. For a long service life and best peace of mind, the battery technology (AGM, EFB, SLI) must match with the vehicle's energy demands. For energy demanding applications, especially for hoteling functions in Long-haul trucks or Caravans the capacity in combination with the recommended Depth-of-Discharge is crucial.

    The VARTA® Partner Portal for our partner workshops and the VARTA® Battery Search for customers makes it easy to select the right battery.

    Go to VARTA® Battery Finder

  • Extending your battery's lifespan involves a few key practices:

    1. Disconnect cables: Always disconnect the negative terminal first to prevent short circuits, then disconnect the positive terminal.
    2. Check battery's state: For non-maintenance-free lead-acid batteries, visit a professional. For maintenance-free batteries, clean vent pipes and avoid checking electrolyte levels.
    3. Start charging: Keep the battery upright if removing from the car. Turn off electrical consumers before connecting the charger. Connect the red cable to positive terminal first, then the black cable to negative terminal.
    4. Stop charging: Switch off charger when fully charged. Disconnect cables starting with the red cable from positive terminal, then the black cable from negative terminal.

    For more information find our article "How to extend the life of your battery".

    Read Article